Part Number Hot Search : 
76MHZ 2SC3039M EL2252CN SBR20 EL2252CN PVC16122 ACX310 APL0200
Product Description
Full Text Search
 

To Download B2001RW Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  key features: ? 20w output power ? 2:1 input voltage range ? 1,500 vdc isolation ? compact 1 x 2 inch case ? single & dual outputs ? optional remote on/off ? industry standard pin-out b2000rw compact 1 x 2 inch 20w wide input range dc/dc con vert ers series input parameter conditions min. typ. max. units input start voltage 12 vdc input 8.6 8.8 9.0 vdc 24 vdc input 17.0 17.5 18.0 48 vdc input 34.0 35.0 36.0 input filter  (pi) filter (complies with en55022 class ?a?) reverse polarity input current 2.0 a short circuit input power 3,500 mw output parameter conditions min. typ. max. units output voltage accuracy 0.5 1.0 % output voltage balance dual output , balanced loads 0.5 2.0 % line regulation vin = min to max 0.1 0.3 % load regulation iout = 10% to 100% 0.1 0.5 % ripple & noise (20 mhz) (note 1) 55 80 mv p - p ripple & noise (20 mhz) over line, load & temp. 100 mv p - p ripple & noise (20 mhz) 10 mv rms output power protection 110 160 % transient recovery time (note 2) 25% load step change 150 300 sec transient response deviation 2.0 4.0 % temperature coef? cient 0.01 0.02 %/c output short circuit continuous (autorecovery) general parameter conditions min. typ. max. units isolation voltage 60 seconds 1,500 vdc isolation test voltage flash tested for 1 sec 1,650 vdc isolation resistance 500 vdc 1,000 m isolation capacitance 100 khz, 1v 1,200 1,500 pf switching frequency 290 330 360 khz remote on/off (note 3) parameter conditions min. typ. max. units supply on 2.5 100.0 vdc supply off 0.0 1.0 vdc standby input current 2 5 ma control common referenced to negative input (pin 2) environmental parameter conditions min. typ. max. units operating temperature range ambient -40 +25 +50 c operating temperature range case +105 c storage temperature range -50 +125 c cooling free air convection humidity rh, non-condensing 95 % rfi six-side shielded metal case conducted emi en55022 class ?a? physical case size 2.0 x 1.0 x 0.40 inches (50.8 x 25.4 x 10.2 mm) case material metal with non-conductive base weight 1.06 oz (30g) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25c, gnd benign 800 khours absolute maximum ratings parameter conditions min. typ. max. units input voltage surge (1 sec) 12 vdc input -0.7 25.0 vdc 24 vdc input -0.7 50.0 48 vdc input -0.7 100.0 lead temperature 1.5 mm from case for 10 sec 260.0 c internal power dissipation all models 4,500 mw caution: exceeding absolute maximum ratings may damage the module. these are not continuous operating ratings. www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com electrical speci cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice.
model number input re ected ripple current (ma, typ) output over voltage protection (vdc) ef ciency (%, typ) capacitive load (? max) fuse rating slow-blow (ma) voltage (vdc) current (ma) voltage (vdc) current (ma, max) current (ma, min) nominal range full-load no-load B2001RW 12 9.0 - 18.0 1,358 30 50 3.3 4,000.0 240.0 3.9 81 470 4,000 b2002rw 12 9.0 - 18.0 1,984 30 50 5.0 4,000.0 240.0 6.8 84 470 4,000 b2003rw 12 9.0 - 18.0 1,898 30 50 12.0 1,670.0 100.0 15.0 88 470 4,000 b2004rw 12 9.0 - 18.0 1,903 30 50 15.0 1,340.0 80.0 18.0 88 470 4,000 b2005rw 12 9.0 - 18.0 1,898 30 50 12.0 835.0 50.0 15.0 88 220 4,000 b2006rw 12 9.0 - 18.0 1,903 30 50 15.0 670.0 40.0 18.0 88 220 4,000 b2011rw 24 18.0 - 36.0 671 17 30 3.3 4,000.0 240.0 3.9 82 470 2,000 b2012rw 24 18.0 - 36.0 980 17 30 5.0 4,000.0 240.0 6.8 85 470 2,000 b2013rw 24 18.0 - 36.0 938 17 30 12.0 1,670.0 100.0 15.0 89 470 2,000 b2014rw 24 18.0 - 36.0 941 17 30 15.0 1,340.0 80.0 18.0 89 470 2,000 b2015rw 24 18.0 - 36.0 938 17 30 12.0 835.0 50.0 15.0 89 220 2,000 b2016rw 24 18.0 - 36.0 941 17 30 15.0 670.0 40.0 18.0 89 220 2,000 b2021rw 48 36.0 - 75.0 335 10 20 3.3 4,000.0 240.0 3.9 82 470 1,000 b2022rw 48 36.0 - 75.0 490 10 20 5.0 4,000.0 240.0 6.8 85 470 1,000 b2023rw 48 36.0 - 75.0 469 10 20 12.0 1,670.0 100.0 15.0 89 470 1,000 b2024rw 48 36.0 - 75.0 471 10 20 15.0 1,340.0 80.0 18.0 89 470 1,000 b2025rw 48 36.0 - 75.0 469 10 20 12.0 835.0 50.0 15.0 89 220 1,000 b2026rw 48 36.0 - 75.0 471 10 20 15.0 670.0 40.0 18.0 89 220 1,000 model selection guide mechanical dimensions heatsink notes: use of the heatsink will extend the units operating temperature range by approximately 10?. the heatsink is black anodized aluminum. micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 ? tel: (781) 344-8226 ? fax: (781) 344-8481 ? e-mail: sales@micropowerdirect.com heatsink dimensions (optional) for heatsink option, add suf? x ?h? to model number (i.e. b2003rw-h ) www.micropowerdirect.com for remote control option, add suf? x ?r? to model number (i.e. b2003rw-r ) mechanical notes: all dimensions are typical in inch es (mm) tolerance x.xx = ?.01 (?.25) pin single dual 1 +vin +vin 2 -vin -vin 3 +vout +vout 4 no pin comm. 5 -vout -vout 6 on/off on/off pin connections derating curve notes: 1. when measuring output ripple, it is recommended that an external 1.0 ? ceramic capacitor be placed from the +vout pin to the -vout pin for single output units and from each output to common for dual output units. 2. transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. the maximum control current at the on/off pin (pin 6) during a logic high is 5 a. the maximum control current to the on/off pin at logic low is -100 a. if the on/off pin is left open, the unit operates. if it is grounded, the unit will shut off. 4. operation at no-load will not damage these units. however, they may not meet all speci cations. 5. dual output units may be connected to provide a 24 vdc or 30 vdc output. to do this, connect the load across the positive (+vout) and negative (-vout) outputs and oat the output common. 6. the converter should be connected to a low ac-impedance source. an input source with a highly inductive impedance may affect the stability of the converter. in applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. in this case, it is recommended that a low esr (esr <1.0 ? at 100 khz) capacitor be mounted close to the converter. for 12v input units, a 22.0 f is recommended; for 24v & 48v units a 6.8 f. 7. it is recommended that a fuse be used on the input of a power supply for protection. see the table above for the correct rating.


▲Up To Search▲   

 
Price & Availability of B2001RW

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X